Worcester Bosch Boiler Losing Pressure in Hull

Worcester Bosch boilers are the most common make we see in Hull, and low pressure is the fault we get called out to most. The awkward part is that Worcester do not use one single code for it, so searching the number on your display often turns up nothing useful.

At a Glance

Hull, East Riding | Worcester Greenstar | No single low pressure code | Worcester’s cold range is 1 to 1.5 bar

Why there is no one Worcester low pressure code

What your boiler shows depends on which model you have. Across the range you may see 1017, CE 207, H07 or 2971, all meaning the system pressure has dropped. H codes are warnings rather than lockouts, so the boiler often keeps running on those while telling you something is wrong.

And plenty of Greenstars show no code at all. The heating just goes off, or runs badly, and the only clue is the pressure gauge sitting down in the red. If your boiler has gone quiet and there is no fault on the screen, check the gauge before anything else.

What pressure should a Worcester be at?

Worcester state that when the heating system is cool, the pressure should be between 1 and 1.5 bar on the gauge. Below 0.5 bar, down in the red section, they say water has been lost from the system and must be replaced.

Always read it cold. The pressure rises as the system heats up, which is normal.

The three ways to top up a Worcester

Worcester describe three filling arrangements, and which one you have depends on your boiler rather than anything you can choose. Look underneath before you start.

External filling loop

A braided hose with a valve at each end, one from the mains cold water and one into the heating. Connect it up, open the mains tap, then open the second tap and watch the gauge. Worcester say to stop once it reaches just about one bar.

Close both taps afterwards.

Keyed internal loop

The key is usually clipped inside a flap underneath the boiler. It fits an open black port on the front right. Slot it in, turn, and watch the pressure rise to just over one bar.

Take the key back out and keep it somewhere you will find it next time.

Keyless internal loop

A blue lever at the bottom of the boiler. Pull it down to let water in and release it once the pressure is over one bar.

The easiest of the three, and the one on most newer Greenstars.

If you put too much in: Worcester’s advice is to bleed a radiator until the gauge comes back between 1 and 1.5 bar. Leaving it overfilled pushes water out of the pressure relief valve and you end up low again by the weekend.

How often is too often?

This is the useful bit, and it comes straight from Worcester. They say the pressure will usually need topping up once or twice a year, and that if you are having to repressurise much more frequently than that, you should contact your installer.

So twice a winter is nothing to worry about. Every month means you have a leak, and all you are doing by topping up is putting fresh water into a system that is losing it.

The one to watch: pressure that climbs too far

Worcester also flag the opposite problem. If the pressure rises by more than 1 bar once the heating is up to temperature, the expansion vessel may need repressurising, and they are clear that this needs a service engineer.

It is worth knowing because it looks like the boiler is fine when cold. The gauge sits where it should, then shoots up when the heating runs, the relief valve lets water go outside, and you are back to low pressure a few days later. Topping it up will never fix that one.

Worcester Losing Pressure More Than Twice a Year?

That is a leak or an expansion vessel, and neither gets better on its own. We service and repair Worcester Bosch boilers across Hull and the East Riding.